Our class that meets at 10AM on Thurs. now has five members and is full. There is still a chance to join the class but a the meeting is now in the evening. There have been many questions about balances needed for the class. I prefer all question be made here so that I don't have to say the samething to many people and most importantly, I can remember who I've said what to.
So to reiterated for all:
The balance is the most important piece of equipment for dyeing. We use it to measure dye, to weigh fibers to check our volumes and other equipment. You could dye with only a balance but there is no piece of equipment that can substitue for a balance. You need a balance that can measure 0.1g accurately, this should be its readability. A readability of 0.01g is not better it is too sensitive and weighs fingerprints, wind gusts.... The smaller the capacity( the maximum it will weigh) the cheaper the balance.
I reccommended some Acculab balances that has caused some problems since they went out of business in Dec.
We have NO remaining stock on the Acculab VIC-1501. Acculab
is a victim of deleveraging and the brand Acculab has terminated
production on December 31, 2010. The information listed below on the
VIC-1501 is for reference only for those people researching the
specification on a VIC1501 scale they already own.
I see on the table there are two balances listed as #1501 but the one
I think you want is VIC -1501 with a capacity of 1500g (more than 3
lbs.) and a readability of 0.1g. Here is another source on the net, http://www.affordablescales.com/scales_mfg1.asp?mfgsrch=Qq1009Xyu14b&fl=19&nm=Acculab_Jewelry_Scales that includes the AC adapter and calibration weights. I hope they still have some!
If not check out this one, http://balance.balances.com/scales/742.
What you need is:
- readability or accuracy of 0.1g (0.01g is not better, it is too tempermental)
- tare
- AC adapter or the ability to run plugged in
- calibration weights, get the ones recommended
What is optional is the capacity. The greater the capacity the
higher the cost. For this class we will be weighing 1 and 5g quantities
mostly. A capacity of 210g would allow you to weigh about a half of a
pound of fiber, 1500g is over 3lbs. The larger the mass of the fiber
the less accuracy required, so sometimes two scales are cheaper than
one.
Anyhow here are some possibilities;
- google sales
- Adam equipment didn't find info on calibration, call before buying
Cathie reccomends scalesgalore,com, Mary called them and they seem to have a good supply of the Acculab VC 1501
Corina asked: Regarding the scale I have one bran name Escali and is 5000g x1g / 200 oz x 0.1 oz
I wandering if it's okay the one I have.
No, this scale will not work to measuring out dye in 1.0g quanties. It is - or + 1g. But it will work for measuring out large amounts of fiber so the balance you buy can have a very small capacity and be cheaper. Examples are : DigiWeigh DW-600BX Pocket Scale, 600x 0.1 g at $29.95 or Ohaus PS121 Pocket Scale , 120x 0.1 g for $35.
A calibration weight is used to determine if the balances is working correctly.
An AC adapter is so that you can plug the balance into the wall and not run on batteries all the time. I think that these small scales only run on batteries. Make sure you have some new ones on hand.
Comments